Clamp reported power for each sensor to 1 microAmp.

Avoids sensors reporting zero power !
Bug: 28980713
Test: Ensure thar power reported in greater than or equal to
     1 microAmperes for all sensors.

Change-Id: I01b40c8a3701d56ded7dcc82e4c7a85b9a8ddc00
diff --git a/services/sensorservice/SensorDevice.cpp b/services/sensorservice/SensorDevice.cpp
index 080c02b..2c4bda9 100644
--- a/services/sensorservice/SensorDevice.cpp
+++ b/services/sensorservice/SensorDevice.cpp
@@ -55,6 +55,9 @@
     if (!connectHidlService()) {
         return;
     }
+
+    float minPowerMa = 0.001; // 1 microAmp
+
     checkReturn(mSensors->getSensorsList(
             [&](const auto &list) {
                 const size_t count = list.size();
@@ -64,6 +67,12 @@
                 for (size_t i=0 ; i < count; i++) {
                     sensor_t sensor;
                     convertToSensor(list[i], &sensor);
+                    // Sanity check and clamp power if it is 0 (or close)
+                    if (sensor.power < minPowerMa) {
+                        ALOGE("Reported power %f not deemed sane, clamping to %f",
+                              sensor.power, minPowerMa);
+                        sensor.power = minPowerMa;
+                    }
                     mSensorList.push_back(sensor);
 
                     mActivationCount.add(list[i].sensorHandle, model);