Merge "Use the new defaultLogFromLevel tracing config option in ProtoLogDataSource" into main
diff --git a/core/java/com/android/internal/protolog/ProtoLogDataSource.java b/core/java/com/android/internal/protolog/ProtoLogDataSource.java
index 6dc6585..5c06b87 100644
--- a/core/java/com/android/internal/protolog/ProtoLogDataSource.java
+++ b/core/java/com/android/internal/protolog/ProtoLogDataSource.java
@@ -17,6 +17,7 @@
 package com.android.internal.protolog;
 
 import static android.internal.perfetto.protos.ProtologConfig.ProtoLogConfig.DEFAULT;
+import static android.internal.perfetto.protos.ProtologConfig.ProtoLogConfig.DEFAULT_LOG_FROM_LEVEL;
 import static android.internal.perfetto.protos.ProtologConfig.ProtoLogConfig.ENABLE_ALL;
 import static android.internal.perfetto.protos.ProtologConfig.ProtoLogConfig.GROUP_OVERRIDES;
 import static android.internal.perfetto.protos.ProtologConfig.ProtoLogConfig.TRACING_MODE;
@@ -43,7 +44,6 @@
 import java.util.HashSet;
 import java.util.Map;
 import java.util.Set;
-import java.util.function.Consumer;
 
 public class ProtoLogDataSource extends DataSource<ProtoLogDataSource.Instance,
         ProtoLogDataSource.TlsState,
@@ -190,73 +190,54 @@
         final Map<String, GroupConfig> groupConfigs = new HashMap<>();
 
         while (configStream.nextField() != ProtoInputStream.NO_MORE_FIELDS) {
-            if (configStream.getFieldNumber() == (int) TRACING_MODE) {
-                int tracingMode = configStream.readInt(TRACING_MODE);
-                switch (tracingMode) {
-                    case DEFAULT:
-                        break;
-                    case ENABLE_ALL:
-                        defaultLogFromLevel = LogLevel.DEBUG;
-                        break;
-                    default:
-                        throw new RuntimeException("Unhandled ProtoLog tracing mode type");
-                }
-            }
-            if (configStream.getFieldNumber() == (int) GROUP_OVERRIDES) {
-                final long group_overrides_token  = configStream.start(GROUP_OVERRIDES);
-
-                String tag = null;
-                LogLevel logFromLevel = defaultLogFromLevel;
-                boolean collectStackTrace = false;
-                while (configStream.nextField() != ProtoInputStream.NO_MORE_FIELDS) {
-                    if (configStream.getFieldNumber() == (int) GROUP_NAME) {
-                        tag = configStream.readString(GROUP_NAME);
+            switch (configStream.getFieldNumber()) {
+                case (int) DEFAULT_LOG_FROM_LEVEL:
+                    int defaultLogFromLevelInt = configStream.readInt(DEFAULT_LOG_FROM_LEVEL);
+                    if (defaultLogFromLevelInt < defaultLogFromLevel.ordinal()) {
+                        defaultLogFromLevel =
+                                logLevelFromInt(configStream.readInt(DEFAULT_LOG_FROM_LEVEL));
                     }
-                    if (configStream.getFieldNumber() == (int) LOG_FROM) {
-                        final int logFromInt = configStream.readInt(LOG_FROM);
-                        switch (logFromInt) {
-                            case (ProtologCommon.PROTOLOG_LEVEL_DEBUG): {
-                                logFromLevel = LogLevel.DEBUG;
-                                break;
-                            }
-                            case (ProtologCommon.PROTOLOG_LEVEL_VERBOSE): {
-                                logFromLevel = LogLevel.VERBOSE;
-                                break;
-                            }
-                            case (ProtologCommon.PROTOLOG_LEVEL_INFO): {
-                                logFromLevel = LogLevel.INFO;
-                                break;
-                            }
-                            case (ProtologCommon.PROTOLOG_LEVEL_WARN): {
-                                logFromLevel = LogLevel.WARN;
-                                break;
-                            }
-                            case (ProtologCommon.PROTOLOG_LEVEL_ERROR): {
-                                logFromLevel = LogLevel.ERROR;
-                                break;
-                            }
-                            case (ProtologCommon.PROTOLOG_LEVEL_WTF): {
-                                logFromLevel = LogLevel.WTF;
-                                break;
-                            }
-                            default: {
-                                throw new RuntimeException("Unhandled log level");
-                            }
+                    break;
+                case (int) TRACING_MODE:
+                    int tracingMode = configStream.readInt(TRACING_MODE);
+                    switch (tracingMode) {
+                        case DEFAULT:
+                            break;
+                        case ENABLE_ALL:
+                            defaultLogFromLevel = LogLevel.DEBUG;
+                            break;
+                        default:
+                            throw new RuntimeException("Unhandled ProtoLog tracing mode type");
+                    }
+                    break;
+                case (int) GROUP_OVERRIDES:
+                    final long group_overrides_token  = configStream.start(GROUP_OVERRIDES);
+
+                    String tag = null;
+                    LogLevel logFromLevel = defaultLogFromLevel;
+                    boolean collectStackTrace = false;
+                    while (configStream.nextField() != ProtoInputStream.NO_MORE_FIELDS) {
+                        if (configStream.getFieldNumber() == (int) GROUP_NAME) {
+                            tag = configStream.readString(GROUP_NAME);
+                        }
+                        if (configStream.getFieldNumber() == (int) LOG_FROM) {
+                            final int logFromInt = configStream.readInt(LOG_FROM);
+                            logFromLevel = logLevelFromInt(logFromInt);
+                        }
+                        if (configStream.getFieldNumber() == (int) COLLECT_STACKTRACE) {
+                            collectStackTrace = configStream.readBoolean(COLLECT_STACKTRACE);
                         }
                     }
-                    if (configStream.getFieldNumber() == (int) COLLECT_STACKTRACE) {
-                        collectStackTrace = configStream.readBoolean(COLLECT_STACKTRACE);
+
+                    if (tag == null) {
+                        throw new RuntimeException("Failed to decode proto config. "
+                                + "Got a group override without a group tag.");
                     }
-                }
 
-                if (tag == null) {
-                    throw new RuntimeException("Failed to decode proto config. "
-                            + "Got a group override without a group tag.");
-                }
+                    groupConfigs.put(tag, new GroupConfig(logFromLevel, collectStackTrace));
 
-                groupConfigs.put(tag, new GroupConfig(logFromLevel, collectStackTrace));
-
-                configStream.end(group_overrides_token);
+                    configStream.end(group_overrides_token);
+                    break;
             }
         }
 
@@ -265,6 +246,18 @@
         return new ProtoLogConfig(defaultLogFromLevel, groupConfigs);
     }
 
+    private LogLevel logLevelFromInt(int logFromInt) {
+        return switch (logFromInt) {
+            case (ProtologCommon.PROTOLOG_LEVEL_DEBUG) -> LogLevel.DEBUG;
+            case (ProtologCommon.PROTOLOG_LEVEL_VERBOSE) -> LogLevel.VERBOSE;
+            case (ProtologCommon.PROTOLOG_LEVEL_INFO) -> LogLevel.INFO;
+            case (ProtologCommon.PROTOLOG_LEVEL_WARN) -> LogLevel.WARN;
+            case (ProtologCommon.PROTOLOG_LEVEL_ERROR) -> LogLevel.ERROR;
+            case (ProtologCommon.PROTOLOG_LEVEL_WTF) -> LogLevel.WTF;
+            default -> throw new RuntimeException("Unhandled log level");
+        };
+    }
+
     public static class Instance extends DataSourceInstance {
 
         public interface TracingInstanceStartCallback {
diff --git a/tests/Internal/src/com/android/internal/protolog/PerfettoProtoLogImplTest.java b/tests/Internal/src/com/android/internal/protolog/PerfettoProtoLogImplTest.java
index 05a68e9..6db5f82 100644
--- a/tests/Internal/src/com/android/internal/protolog/PerfettoProtoLogImplTest.java
+++ b/tests/Internal/src/com/android/internal/protolog/PerfettoProtoLogImplTest.java
@@ -798,6 +798,38 @@
                 .isEqualTo("My Test Debug Log Message true");
     }
 
+    @Test
+    public void usesDefaultLogFromLevel() throws IOException {
+        PerfettoTraceMonitor traceMonitor =
+                PerfettoTraceMonitor.newBuilder().enableProtoLog(LogLevel.WARN).build();
+        try {
+            traceMonitor.start();
+            mProtoLog.log(LogLevel.DEBUG, TestProtoLogGroup.TEST_GROUP,
+                "This message should not be logged");
+            mProtoLog.log(LogLevel.WARN, TestProtoLogGroup.TEST_GROUP,
+                "This message should logged %d", 123);
+            mProtoLog.log(LogLevel.ERROR, TestProtoLogGroup.TEST_GROUP,
+                "This message should also be logged %d", 567);
+        } finally {
+            traceMonitor.stop(mWriter);
+        }
+
+        final ResultReader reader = new ResultReader(mWriter.write(), mTraceConfig);
+        final ProtoLogTrace protolog = reader.readProtoLogTrace();
+
+        Truth.assertThat(protolog.messages).hasSize(2);
+
+        Truth.assertThat(protolog.messages.get(0).getLevel())
+                .isEqualTo(LogLevel.WARN);
+        Truth.assertThat(protolog.messages.get(0).getMessage())
+                .isEqualTo("This message should logged 123");
+
+        Truth.assertThat(protolog.messages.get(1).getLevel())
+                .isEqualTo(LogLevel.ERROR);
+        Truth.assertThat(protolog.messages.get(1).getMessage())
+                .isEqualTo("This message should also be logged 567");
+    }
+
     private enum TestProtoLogGroup implements IProtoLogGroup {
         TEST_GROUP(true, true, false, "TEST_TAG");