thermal: Update thermal table

Change CdevFloorWithPowerLink for fcc at MODERATE from 1 to 0 to avoid
unwanted throttling from fcc when wlc_fcc is set to 0 with ODPM-lo.

Bug: 192281595
Test: Boot & check log
Change-Id: I718eeb1c3c325a34345a24de90669f349addc972
diff --git a/thermal_info_config_oriole.json b/thermal_info_config_oriole.json
index 37b452a..bfcf177 100644
--- a/thermal_info_config_oriole.json
+++ b/thermal_info_config_oriole.json
@@ -336,7 +336,7 @@
                     "LimitInfo": [0, 2, 3, 4, 4, 4, 4],
                     "BindedPowerRail": "POWER_FOR_CHARGING_THROTTLING",
                     "PowerThreshold": [500, 500, 500, 500, 0, 0, 0],
-                    "CdevFloorWithPowerLink": [0, 0, 1, 2, 4 ,4 ,4],
+                    "CdevFloorWithPowerLink": [0, 0, 0, 2, 4 ,4 ,4],
                     "ReleaseLogic": "RELEASE_TO_FLOOR",
                     "ThrottlingWithPowerLink":true
                 },
diff --git a/thermal_info_config_raven.json b/thermal_info_config_raven.json
index ca2da49..1336c62 100644
--- a/thermal_info_config_raven.json
+++ b/thermal_info_config_raven.json
@@ -336,7 +336,7 @@
                     "LimitInfo": [0, 2, 3, 4, 4, 4, 4],
                     "BindedPowerRail": "POWER_FOR_CHARGING_THROTTLING",
                     "PowerThreshold": [500, 500, 500, 500, 500, 0, 0],
-                    "CdevFloorWithPowerLink": [0, 0, 1, 2, 3 ,4 ,4],
+                    "CdevFloorWithPowerLink": [0, 0, 0, 2, 3 ,4 ,4],
                     "ReleaseLogic": "RELEASE_TO_FLOOR",
                     "ThrottlingWithPowerLink":true
                 },